Abstract
A general solution for initial position and magnet polarity estimation on PM machines is presented. The technique is based on carrier frequency signal injection and proves to be fast, simple and parameter insensitive. It is applied to both salient and very low saliency PM synchronous machines of different power levels. An important step to understanding the implementation is to map the saliency and magnet polarity information as a function of rotor position. A state filter topology is proposed to ensure fast, smooth and robust convergence of the initial position and magnet polarity estimation for a SPMSM with an extremely low saliency ratio. Test results demonstrate consistent performance across different machine types
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.