Abstract

The ozone generation systems generally use the pulse amplitude modula­tion (PAM) to vary or control the ozone concentration. The results obtained after the implementation of pulse density modulation (PDM) in the power supply system of an ozone generation and the improvement achieved in the efficiency curve is presented in this paper. PAM and PDM techniques were applied in ozone generation system with push-pull inverter resonant self. The adjusted voltage amplitude of the PDM waveform power is de­termined from the condition of the PAM waveform where the maximum efficiency was obtained; Thus achieving increased efficiency in 60% of operating points ozone generation system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.