Abstract
The demonstrated efficacy of implantable cardioverter-defibrillators (ICDs) for reducing sudden death in heart failure trial populations presents a critical challenge to those responsible for the allocation of healthcare resources.1–3 The current cost, multiplied by the prevalence of heart failure deemed high-risk, threatens to make this one enterprise the highest priced intervention for the Medicare population. The elegant cost-effectiveness analysis contributed by Dr Mark and colleagues from the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) in this issue of Circulation provides an exemplary insight into this challenge.4 These investigators’ favorable conclusions are consistent with those from a meta-analysis by Sanders et al5 and with the slightly more conservative implications from the recent cost-effectiveness analysis of the Multicenter Automatic Defibrillator Implantation Trial (MADIT)-II by Zwanziger et al.6 Article p 135 This editorial will offer an alternative conclusion based on both back-of-the-envelope estimations and scrutiny of model assumptions regarding different phases of survival for heart failure populations. ICDs for primary prevention of sudden death in the heart failure population may be less cost-effective than other recommended heart failure therapies, which are prescribed to modify disease progression and symptoms, decreasing costly hospitalizations as well as mortality. Formal cost-effectiveness analysis is complex, but it may be illustrative to begin from simple considerations. A reasonable threshold for cost-effective intervention is often assigned as $40 000 per life-year saved, in line with the present article4 suggesting a cost of $38 389 per life-year saved and $41 530 per quality-adjusted life-year saved. This is approximately equal to the cost of the defibrillator device and implantation, as currently assessed for reimbursement. (The costs would be lower for the simpler device used in SCD-HeFT, which is not available now, and for outpatient implantation, which was common in SCD-HeFT but not the current standard.) This …
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.