Abstract
The development of a deep wound infection in the presence of internal hardware presents a clinical dilemma. The purpose of the present study was to evaluate the treatment outcomes of vancomycin cement with other advances of surgical techniques for implant-related infection (IRI) in the tibia. This study included 217 consecutive patients who had sustained IRI of the tibia. Of them, 152 patients had soft tissue defects and the internal hardware was exposed. Repeated debridement and negative pressure assisted closure were used. All the infected internal hardware was removed. External fixations and flaps were used. Custom-made vancomycin cement was inserted into the dead space of the wounds and left in site for a month. The follow-up was from 12 months to 108 months, averaging 37.5 months. For all the 217 patients, the general osteomyelitis healing rate and bone union rate were 86.6% and 97.2%, respectively. This study shows high rates of healing of IRI in the tibia if the new advances of surgery could be effectively combined into the treatment strategy with vancomycin cement as an important treatment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.