Abstract
Wafer temperature during implant has a dominate effect on the amorphous layer thickness and post anneal residual defects which can result in difference in device performance and difficulties in tool matching between different implant systems, namely batch type vs. single wafer implanter and spot beam vs. ribbon beam system. Although the implant temperature set point can be well defined and controlled, the instantaneous temperature on wafer during implant is quite complicated interactions among beam shape, dose rate, duty cycle and cooling system to the behavior of defect generation and dynamic annealing. A batch system, iStar, and a single wafer system, iPulsar, which delivers both spot beam and ribbon beam with cold implant capability were used to study the effect of implant temperature to the post anneal residual defects by BF2 15 keV 3×1015 cm−2 implant after 850 °C/30s anneal. Measurements from Rs, SIMS, plane view TEM are compared and analyzed. The results by ribbon beam and spot beam are also compared.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.