Abstract

Cementless medial unicondylar knee prostheses with mobile inlays have proved to be successful and are increasingly being used worldwide; however, there is a risk of fracture of the medial tibial plateau in the postoperative healing phase. In most cases we observed split fractures starting from the keel of the implant. These can be treated with a small posteromedial locking plate, whereby the upper screws are inserted through the keel slot and then interlocked. This achieves an optimally strong bond between the implant and the screws and a stable construct. A longitudinal skin incision is made at the level of the keel slot. A radial T‑plate is placed subcutaneously. The plate is fixed with a lag screw in the middle section. The compression usually closes the fracture gap. Then three locking cortical bone screws are inserted through the keel slot in the transverse section of the plate. Distal fixation by locking or standard screws. Immediate pain-adapted partial weight bearing, unrestricted mobility. Healing of the fracture and full weight bearing mostly achieved after 4weeks.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.