Abstract

For the first time, we present a novel technique that enables the exchange of the Impella CP (Abiomed Inc., Danvers, Massachusetts, USA) to the Impella 5.5 (Abiomed Inc.) with no interruption of mechanical support in patients with minimal left ventricular reserve. Specifically, the aortic valve is crossed with the Impella 5.5 whereas the Impella CP is still functioning within the left ventricle. The Impella 5.5 is then initiated, and the Impella CP is weaned. Finally, the Impella CP is pulled out into the descending aorta. This exchange provides continuous support with no hemodynamic disarrangement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.