Abstract
ABSTRACTAn impedance method was developed for the estimation of coliforms in raw and pasteurized milk, heavy cream, and ice cream mix. Impedance detection times (IDTs) in CM, a medium developed for the impedimetric detection of coliforms, were compared to confirmed Violet Red Bile Agar (CVRBA) plate counts. Correlations of 0.91–0.95 between the two methods were obtained for the four dairy products. The line equations of these relationships were similar for all products. An IDT shorter than 9 hr was indicative of coli‐ form levels >10/mL, while an IDT longer than 12 hr was indicative of levels <10/mL. The impedhnetric estimation of coliforms provided the same information as CVRBA counts from dairy products, offering a savings in time and labor.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.