Material balance calculation was adopted to a bubbling desulfurization system of 600MW unit for water-saving measures. Analysis was made on main factors affecting water consumption. Results showed that heat release of desulfurization reaction and water evaporation went up with sulfur content increasing; Free water and bound water in gypsum increased rapidly with calcium improved; When sulfur content enhanced from 0.5% to 3.5%, water evaporation of reactor increased by 28.9% and waste water increased by 7.8%; With inlet flue temperature of WFGD raised from 120°C to 200°C, waste water increased by 25.3% and evaporation of water increased by 102.35%; Once gas-gas heater (GGH) was installed, heat release of original flue gas decreased by 43.72% and the total water consumption decreased by 39.06%. Therefore, with sulfur content and temperature of inlet flue increasing, water consumption raises. Installation of gas-gas heater (GGH) can effectively reduce water consumption of WFGD system.