Abstract

Fill media and excavation volume are the main costs in constructing bioretention cells, but the importance and impact of media depth in these systems is relatively unknown. Two sets of loamy-sand-filled bioretention cells of two media depths (0.6 m and 0.9 m), located in Nashville, North Carolina, were monitored from March 2008 to March 2009 to examine the impact of media depth on their performance with respect to hydrology and water quality. Construction and design errors resulted in the surface storage volume being undersized for the design event (2.5 cm). The actual surface storage volume was only 28% and 35% of the design volume for the 0.6-m and 0.9-m media depth cells, respectively. Overflow (bypass) occurred at least three times more frequently than intended. The exfiltration volume was much higher in the deeper media cells, presumably because of greater storage volume in the media and more exposure to side walls. Evapotranspiration (ET) plus exfiltration accounted for 42% of the inflow runoff in t...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.