Abstract

We present a prospective study of impaction grafting using collared textured stems in femurs with massive defects (defined as requiring >150 cm 3 of cancellous allograft). Eighteen hips were followed for a minimum of 2 years. Average Harris hip scores increased from 50 preoperatively to 83 at most recent follow-up. Seventeen hips were functioning well at the time of most recent follow-up and exhibited no stem subsidence or aseptic loosening. One hip was associated with visible subsidence and required further revision. Single-photon emission computed tomography analyses performed at an average of 37 months indicated active graft reorganization in all cases studied. Impaction allografting with collared textured stems for massive defects demonstrates good intermediate-term clinical results and may be a useful alternative to allograft stem composites and megaprostheses.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.