Abstract

The total ionizing dose response of a triple-level-cell (TLC) NAND flash is shown to be low enough that data corruption can occur as a result of an x-ray inspection. Only a few seconds of x-ray exposure corresponding to a total dose of merely 50 rad(Si) in a real-time x-ray source are required to induce errors. An in-depth total dose analysis shows which pages of the memory and data patterns are the most susceptible to radiation. The results show that TLC NAND flash devices are not suitable for use in high radiation environments, and that care must be taken when exposing them to even small x-ray exposures like those present in a circuit board inspection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.