Abstract
Late gadolinium enhancement (LGE) imaging in patients with implantable cardioverter-defibrillators (ICD) is limited by device-related artifacts (DRA). The use of wideband (WB) LGE protocols improves LGE images, but their efficacy with different ICD types is not well known. To assess the effects of WB LGE imaging on DRA in different non-MR conditional ICD subtypes. Retrospective. A total of 113 patients undergoing cardiac magnetic resonance imaging with three ICD subtypes: transvenous (TV-ICD, N=48), cardiac-resynchronization therapy device (CRT-D, N=48), and subcutaneous (S-ICD, N=17). 5 T scanner, standard LGE, and WB LGE imaging with a phase-sensitive inversion recovery segmented gradient echo sequence. DRA burden was defined as the number of artifact-positive short-axis LGE slices as percentage of the total number of short-axis slices covering the left ventricle from based to apex, and was determined for WB and standard LGE studies for each patient. Additionally, artifact area on each slice was quantified. Shapiro-Wilks, Kruskal-Wallis analysis of variance, Dunn tests with Bonferroni correction, and Mann-Whitney U-test. In patients with TV-ICD, DRA burden was significantly reduced and nearly eliminated with WB LGE compared to standard LGE imaging (median [interquartile range]: 0 [0-7]% vs. 18 [0-50]%, P< 0.05), but WB imaging had less of an impact on DRA in the CRT-D (8 [0-23]% vs. 16 [0-45]%, p=0.12) and S-ICD (60 [15-71]% vs. 67 [50-92]%, P= 0.09) patients. Residual DRA was significantly greater (P< 0.05) for S-ICD compared to other device types with WB LGE imaging, despite the generators of all three ICD types having similar proximity to the heart. The area of S-ICD associated DRA was smaller with WB LGE (P< 0.001) than with standard LGE imaging and the artifacts had different characteristics (dark signal void instead of a bright hyperenhancement artifact). Although WB LGE imaging reduced the burden of DRA caused by S-ICD, the residual artifact was greater than that observed with TV-ICD and CRT-D devices. Further developments are needed to better resolve S-ICD artifacts. 1 TECHNICAL EFFICACY: STAGE: 5.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.