Abstract
Abstract Funding Acknowledgements Type of funding sources: None. Background Despite the known benefits of physical activity, patients with cardiovascular disease do not practice enough nor maintain a regular physical activity for their health [1-4] . Walking is one of the easiest ways to stay physically active and can be implemented easily in everyday life [5]. Wearable physical activity monitoring devices have the potential to help increase physical activity through self-monitoring and feedback. Purpose To review randomized controlled trials using wearable physical activity monitoring device as an intervention to increase daily walking activity and improve physical capacities in cardiovascular diseases (CVD) patients. Methods Design: Systematic review and meta-analysis of randomized controlled trials (RCTs). Data Sources: PubMed, Embase, Web of Science. Eligibility criteria: Randomized controlled studies including patients over 18 years of age with CVD comparing an intervention group using a wearable physical activity monitoring device with feedback to usual care or to a control group receiving no feedback on their physical activity and reporting a change in the daily number of steps and/or a change in the distance covered in the 6-minute walking test (6MWT) or a change in peak oxygen uptake (VO2 peak). Outcomes: Primary outcome was daily number of steps, secondary ouctomes were distance covered in the 6-minute walking test (6MWT) and/or peak oxygen uptake (VO2 peak). Results Sixteen RCTs were included. The intervention of wearing a physical activity monitoring device with feedback significantly improved daily number of steps compared with controls (standardized mean difference ((SMD) 0.85; 95% CI [0.42; 1.27], p < 0.01). The effect was greater when the duration of the intervention was less than 3 months (SMD 1.0; 95% CI [0.18; 1.82], p < 0.01) than when the duration of the intervention was 3 months or longer (SMD 0.71; 95% CI [0.27; 1.16], p < 0.01) but no significant interaction was found between subgroups (p = 0.55). Six MWT distance and VO2 peak showed only small effects (SMD 0.34 (95% CI [-0.11; 0.80], p = 0.02) and SMD 0.53 (95% CI [0.03; 1.03], p = 0.07), respectively).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.