Abstract

In recent years, CAD/CAM technology has allowed indirect ceramic restorations to become a part of everyday chairside clinical practice. Therefore, the impact of different cavity-preparation designs on the fracture resistance of CAD/CAM fabricated ceramics was assessed in this study. Three designs of cuspal covering (none, palatal, and entire) and two widths of the occlusal isthmus (75% and 100% of the intercuspal distance) were used for the preparation of inlays and onlays to form six groups (n = 10/group). Moreover, thermomechanical cyclic loading was applied to every tooth under a chewing simulator. A universal testing machine was used to measure each group’s fracture resistance. The tested specimens were inspected for any signs of fractures and cracks to categorize failure patterns. Thereby, the values of fracture strength showed that there were statistically nonsignificant differences between the tested groups (p < 0.05). However, a significant difference (p = 0.01) was found between group 1 (inlays) (1950 ± 405) and group 6 (onlays) (3900 ± 770). Type III or type IV fracture modes were seen in the majority of the specimens. In conclusion, inlays and onlays made of zirconia using CAD/CAM technology were deemed reliable for restoring premolars, irrespective of the cavity-preparation design, except for inlays with a 75% intercuspal distance.