Abstract

BackgroundTwo-dimensional (2D) and three-dimensional (3D) computed tomography (CT) have been increasingly used in various intra-articular fractures including pilon fracture. However, no study has investigated intraobserver and interobserver reliabilities of pilon fracture classification using 3D CT images. Hypothesis(1) Intraobserver and interobserver agreements of fracture classifications and treatment recommendations will improve by using 2D CT images compared to using plain radiographs only; (2) agreements will improve by adding 3D CT images compared to adding 2D CT images; and (3) agreements of orthopedic residents rather than specialists will be influenced more by imaging modality. Materials and methodsTen orthopedic specialists and 10 residents completed a survey to classify the fractures according to the Rüedi-Allgöwer and AO/OTA classifications and to select treatment options using 25 pilon fracture images. The survey was conducted using plain radiographs, with 2D and 3D CT images introduced 3 and 6weeks later, respectively. Kappa coefficients were calculated to determine reliabilities. ResultsIntraobserver reliabilities for fracture classifications in specialists significantly improved by using 2D images compared to using plain radiographs only. Addition of 3D CT did not significantly improve intraobserver reliabilities compared to those with 2D CT. Use of 2D CT images significantly improved overall interobserver agreement of both classifications, with the improvement being greater for residents. Use of 3D CT images did not improve the interobserver reliability of both classifications. Overall interobserver reliabilities for treatment recommendations did not significantly differ according to the imaging modality. However, interobserver agreement among residents significantly improved from slight agreement using radiographs only to fair agreement using 2D CT images. DiscussionIntraobserver and interobserver reliabilities of pilon fracture classification and treatment recommendations did not improve between using 3D and 2D CT. Using 2D CT images improved the intraobserver and interobserver reliabilities of the fracture classifications in specialists and the interobserver reliabilities of the fracture classifications and the treatment recommendations in residents. Level of evidenceIV, case control study.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.