Abstract

The success of dynamic materials properties research at Sandia National Laboratories has led to research into ultralow impedance, compact pulsed power systems capable of multi-MA shaped current pulses with rise times ranging from 220 to 500 ns. The Genesis design consists of two hundred and forty 200 kV, 80 kA modules connected in parallel to a solid dielectric disk transmission line and is capable of producing 280 kbar of magnetic pressure (>; 500 kbar pressure in high Z materials) in a 1.75 nH, 20-mm wide stripline load. Stripline loads operating under these conditions expand during the experiment resulting in a time-varying load that can impact the performance and lifetime of the system. This paper provides analysis of time-varying stripline loads and the impact of these loads on system performance. Further, an approach to reduce dielectric stress levels through active damping is presented as a means to increase system reliability and lifetime.