Abstract

To make fuel rods more resistant to grid-to-rod fretting or other cladding penetration failures, the cladding thickness could be increased or strengthened. Implementation of thicker fuel rod cladding was evaluated for the NPP Krško that uses 16 × 16 fuel design. Cladding thickness of the Westinghouse standard fuel design (STD) and optimized fuel design (OFA) is increased. The reactivity effect during the fuel burnup is determined. To obtain a complete realistic view of the fuel behaviour a typical, near equilibrium, 18-month fuel cycle is investigated. The most important nuclear core parameters such as critical boron concentrations, isothermal temperature coefficient and rod worth are determined and compared.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call