Abstract

The unbalanced magnetic pull (UMP) of hydro turbine generating sets (HTGS) is one of the main reason induced vibration of the HTGS and the power plant. To study the effects of UMP on the shaft vibration characteristics of HTGS, this article constructs whole HTGS system which include hydraulic turbine and its hydraulic system, generator, transient model of the HTGS shafting, excitation and governing system, to simulate the actual operation of HTGS. The shafting vibration is simulated under different characteristics of UMP, simulation shows that the frequency resonance zone of the UMP has large influence on the shafting vibration. And then, the improved Prony algorithm is applied to extract the shafting oscillation characteristics of HTGS, and is effective. It provides a good method to research the effect of frequency and amplitude changes of UMP on the shafting vibration.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.