Abstract

PurposePulmonary vein isolation (PVI) through catheter ablation is the basis for the treatment of atrial fibrillation (AF). The left common ostium (LCO) is a high prevalence anatomical variation and has conflicting results in the effects on the prognosis following ablation. We undertook a systematic review and meta‐analysis of studies that compared the arrhythmia recurrence rate after radiofrequency ablation or cryoablation balloon between patients with normal pattern pulmonary vein and patients with LCO.Methods and ResultsResults were pooled using a fixed or random effect, at the discretion of heterogeneity (>25%), in addition, we associated subgroup analysis in these cases and when clinically indicated. Fourteen non‐randomized studies totaling 3278 patients were included. In analyses using the two energies all patients: OR 1.01 (95% CI 0.84–1.23; P = .90, I 2 = 67%) and excluding patients with any type of persistent AF (PeAF) and those submitted to linear atrial lesion (LAL) OR 0.80 (95% CI 0.52–1.22; P = .30, I 2 = 71%). Using CRYO: all patients OR 1.34 (95% CI 1.03–1.74; P = .03, I 2 = 0%). Using RF: all patients—OR 0.55 (95% CI 0.32–0.95; P = .03, I 2 = 49%); excluding studies with long duration PeAF and the performance of LAL concomitant—OR 0.45 (95% CI 0.23–0.91; P = .03, I 2 = 44%).ConclusionThe results suggest a better prognosis in patients with LCO, submitted to PVI without additional LAL under RF energy in paroxysmal AF and short‐duration PeAF. In patients undergoing CRYO, the presence of LCO suggests a worse prognosis.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call