Abstract

OBJECTIVE Target depth, defined by the z-coordinate in the dorsoventral axis relative to the anterior commissure–posterior commissure axial plane of the MR-guided focused ultrasound (MRgFUS) lesion, is considered to be critical for tremor improvement and the occurrence of side effects such as gait impairment. However, although different z-coordinates are used in the literature, there are no comparative studies available with information on optimal lesion placement. This study aimed to compare two different MRgFUS lesion targets (z = +2 mm vs z = 0 mm) regarding efficacy and safety outcomes. METHODS The authors conducted a retrospective analysis of 52 patients with pharmacoresistant tremor disorders who received unilateral MRgFUS thalamotomy in the ventral intermediate nucleus for the first time between 2017 and 2022 by one neurosurgeon, with two different z-coordinates, either z = +2 mm (+2-mm group; n = 17) or z = 0 mm (0-mm group; n = 35), but otherwise identical parameters. Standardized video-recorded assessments of efficacy (including the Washington Heights-Inwood Genetic Study of Essential Tremor scale) and safety (using a standardized grading system) outcomes at baseline and at 6 months posttreatment were reviewed and compared. Moreover, overall patient satisfaction was extracted as documented by the examiner at 6 months. RESULTS Based on a multiple logistic regression analysis, the authors found that a more dorsal target with a z-coordinate of +2 mm as compared with 0 mm was associated with a higher incidence of any persistent side effect at 6 months (p = 0.02). Most consistently, sensory disturbances, although mild and nondisturbing in most cases, occurred more frequently in the +2-mm group (35% vs 11%, p = 0.007), while no significant differences were found for gait impairment (29% vs 35%) and arm ataxia (24% vs 11%). On the other hand, average tremor suppression was similar (63.6% vs 60.2%) between the groups. Here, higher efficacy was associated with a higher side effect burden in the 0-mm group but not in the +2-mm group. Despite the occurrence of side effects, general patient satisfaction was high (87% would undergo MRgFUS again) as most patients valued tremor suppression more. CONCLUSIONS A more ventral MRgFUS target of z = 0 mm seems to be associated with a more favorable safety and a comparable efficacy profile as compared with a more dorsal target of z = +2 mm, but prospective studies are warranted.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call