Abstract

In hospitals, sinks act as reservoirs for bacterial pathogens. To assess the extent of splashing, fluorescein dye was added to four hospital sinks previously involved in pathogen dispersal to the environment and/or transmission to patients, and one sink that was not. Applying dye to the p-trap or tailpiece did not result in any fluorescent droplets outside of the drain. When applied to the drain, droplets were found in all but one wash basin, and this was more common in the absence of a drain plug. Sink design considerations to install drain plugs, reduce dripping and offset the tap may help to prevent transmission from drains.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.