To determine the diagnostic performance of simulated reduced-dose chest CT scans regarding pulmonary T1 tumors and assess the potential impact on patient management, a repository of 218 patients with histologically proven pulmonary T1 tumors was used. Virtual reduced-dose images were simulated at 25%- and 5%-dose levels. Tumor size, attenuation, and localization were scored by two experienced chest radiologists. The impact on patient management was assessed by comparing hypothetical LungRADS scores. The study included 210 patients (41% females, mean age 64.5 ± 9.2 years) with 250 eligible T1 tumors. There were differences between the original and the 5%-but not the 25%-dose simulations, and LungRADS scores varied between the dose levels with no clear trend. Sensitivity of Reader 1 was significantly lower using the 5%-dose vs. 25%-dose vs. original dose for size categorization (0.80 vs. 0.85 vs. 0.84; p = 0.007) and segmental localization (0.81 vs. 0.86 vs. 0.83; p = 0.018). Sensitivities of Reader 2 were unaffected by a dose reduction. A CT dose reduction may affect the correct categorization and localization of pulmonary T1 tumors and potentially affect patient management.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.