Abstract
The impact of different shear connectors (perfobond leisten (PBL) shear connectors and stud shear connectors) on the mechanical performances of prestressed concrete (PSC) composite box-girders with corrugated steel webs was studied. Mechanical properties were researched by conducting experiments on two specimens with PBL shear connectors or stud shear connectors; these properties included the ultimate bearing capacity, the flexural stiffness, crack resistance and the efficiency of prestressing of the girder. The test results showed that, compared with the stud shear connectors, PBL shear connectors greatly improved the ultimate bearing capacity, flexural stiffness and crack resistance of PSC composite box-girders with corrugated steel webs. However, regarding the efficiency of prestressing, the PBL shear connectors did not perform as well as the stud shear connectors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Proceedings of the Institution of Civil Engineers - Structures and Buildings
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.