Abstract

This paper studies the impact of sensor measurement error on designing a water quality monitoring network for a river system, and shows that robust sensor locations can be obtained when an optimization algorithm is combined with a statistical process control (SPC) method. Specifically, we develop a possible probabilistic model of sensor measurement error and the measurement error model is embedded into a simulation model of a river system. An optimization algorithm is used to find the optimal sensor locations that minimize the expected time until a spill detection in the presence of a constraint on the probability of detecting a spill. The experimental results show that the optimal sensor locations are highly sensitive to the variability of measurement error and false alarm rates are often unacceptably high. An SPC method is useful in finding thresholds that guarantee a false alarm rate no more than a pre-specified target level, and an optimization algorithm combined with the thresholds finds a robust sensor network.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call