Abstract

Complying with strict PM10 and PM2.5 limit values poses challenges in many European regions, influenced by diverse factors such as natural, regional, and local anthropogenic sources. Urban air pollution, exacerbated by road transport, local industry, and dust resuspension, contrasts with rural areas affected by solid fuel-based local heating and increasing wood burning. This study focuses on village of Sučany, located in Slovakia, analysing PM concentrations during non-heating and heating seasons. The method of analysis relies on the use of the MP101M air quality analyser that utilises beta radiation absorption method. One set of measurements was conducted at five distinct locations during the heating season (18/01/2019 to 28/02/2019) and non-heating season (14/08/2018 to 1/10/2018). Significant differences emerged during the non-heating season with corresponding PM10 averages of 23.0 µg/m3 and PM2.5 at 19.3 µg/m3. In contrast, the PM10 averaged 53.9 µg/m3 and 52.8 µg/m3 during the heating season. The heating season shows PM2.5 contributing up to 98% of total PM10. The distribution of PM10 and PM2.5 pollution and the location of the potential source obtained using polar plots differed during the heating and non-heating seasons. This research underscores the impact of local heating on air quality in a typical Slovak village. The key recommendation for targeted interventions is supporting up-to-date air quality data, education, and financial incentives for citizens in order to implement cleaner and modern heating solutions.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call