Abstract

Reported values of D2 receptor occupancy (RO) achieved by antipsychotic drugs tend to be lower when measured with 123I-IBZM SPECT than with 11C-Raclopride PET. Image degrading factors such as attenuation, distance-dependent collimator response and scatter could account for this difference. While attenuation correction is routinely applied to SPECT images, the other degradations are not usually accounted for. The aim of this work was to assess the impact of scatter correction on D2 RO quantification with 123I-IBZM SPECT, and to compare the results of both corrected and un-corrected SPECT values with 11C-Raclopride PET measurements. Phantom experiments as well as within-subject human data from a previous study were used for this purpose. SPECT images were reconstructed using filtered back-projection including attenuation correction (FBPA), ordered subsets expectation maximization including attenuation and point spread function corrections (OSEMA+PSF) and ordered subsets expectation maximization including attenuation, point spread function and scatter corrections (OSEMA+PSF+SCT). PET images were reconstructed using the FBP algorithm and corrected for attenuation, scatter, random coincidences and dead time. Quantification of receptor availability was performed using the tissue ratio at pseudoequilibrium for SPECT, and the simplified reference tissue model (SRTM) for PET. Analysis was performed using both occipital cortex (occ) and cerebellum (cer) as reference regions for both modalities. When images were reconstructed using FBPA, SPECT D2 RO values were significantly lower as compared with PET leading to a D2 RO difference of −20% (CI95%: −13, −27%) (occ) and −23% (CI95%: −14, −31%) (cer). When images were reconstructed using OSEMA+PSF, SPECT D2 RO values were also lower as compared with PET leading to a D2 RO difference of −21% (CI95%: −14, −27%) (occ) and −24% (CI95%: −18, −30%) (cer). When images were reconstructed using OSEMA+PSF+SCT, the D2 RO bias was reduced to −6% (CI95%: 0, −13%) (occ) and −11% (CI95%: −4, −18%) (cer). These data suggest that the scatter correction plays a major role in explaining the differences between D2 RO measurements using 123I-IBZM SPECT and 11C-Raclopride PET.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.