Abstract

The pre-polymerization temperature of resin composite restorative materials could influence their adaptation to cavity details. As a current debate is existing about the refrigeration of resin composite restorative materials, this study was designed to assess the effect of refrigeration of 3 types of resin composite restorative materials with different matrix systems on their marginal adaptation in Class II restorations. Forty-two sound maxillary molars, each with two separated Class II cavities, were used in this study. The teeth were assigned into 3 main groups (n = 14) according to the restorative /adhesive system used; an Ormocer-based composite (Admira Fusion/Futurabond M+, Voco GmbH, Cuxhaven, Germany), a methacrylate modified Ormocer-based (Ceram.X SphereTEC One/Prime&Bond Universal, Dentsply Sirona GmbH Konstanz, Germany), and a methacrylate-based (Tetric N-Ceram/Tetric N-Bond Universal, Ivoclar Vivadent AG, Schaan, Liechtenstein). Each group was then divided into 2 subgroups (n = 14) according to the gingival margin location; 1mm above and 1mm below the cemento-enamel junction (C.E.J). Each subgroup was further divided into 2 categories (n = 7) according to the storage temperature; stored at room temperature or stored in refrigerator at 4°- 5° C. Epoxy resin replicas were observed under scanning electron microscope (SEM) to examine the marginal gaps. A gab scoring system was used to assess the marginal adaptation of each restoration by giving scores on the basis of measurements of the maximum marginal gaps. The data obtained were statistically analyzed using the Chi-square test at a significance level of p < 0.05. None of the tested groups exhibited 100% gap-free margins irrespective of margin location or storage temperature. For both storage temperatures, no statistically significant difference was observed among all tested groups either with margins located above or below C.E.J (p > 0.05). As well, there was no statistically significant difference when comparing both marginal locations for each material (p > 0.05). Regarding the effect of storage temperature, statistically significant difference was only observed between the room-temperature stored groups with margins located above C.E.J and their corresponding groups stored in refrigerator (p < 0.05). The refrigeration of resin composite restorative materials prior to the restorative procedures revealed a deleterious effect on marginal adaptation of the restorations with margins located in enamel regardless the type of material used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.