Abstract

Megasonic cleaning using de-gassed water (less than 2ppm N2, O2, CO2) in a 300mm batch immersion tool often does not give optimal particle performance, with particle streaks and clusters added onto the wafer, and low particle removal efficiency (PRE). When water was re-gasified with N2, the resultant stable cavitation activity reduced particle adders and increased PRE. With N2 concentration increased to just above 5ppm, number of particle adders decreased by three folds. Optimal particle performance could be obtained by operating at an N2 level close to saturation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.