Abstract

Nowadays laparoscopic approach is accepted as a valid alternative to open surgery for the treatment of colorectal cancer. Several studies consider this approach to be safe and feasible also in obese patients, even if dissection in these patients may require a longer operative time and involve higher blood loss. To facilitate laparoscopic approach, more difficult in these patients, several energy sources for laparoscopic dissection and sealing, has been adopted recently. The aim of this study is to investigate the possible intraoperative advantages of radiofrequency energy in terms of blood loss and operative time in obese patients undergoing laparoscopic resection for cancer. All patients who underwent laparoscopic surgery for colorectal cancer from January 2010 to December 2015 were registered in a prospective database. Patients with a body mass index BMI (kg/m2)≥30 were defined as obese, and patients with a BMI (kg/m2)<30 were defined as non-obese. All 136 obese patients observed were divided retrospectively into 2 groups according to the devices used for dissection: 83 patients (Historical group: B) on whom dissection and coagulation were performed using other energy sources (monopolar electrocautery scissors, bipolar electrical energy, ultrasonic coagulating shears) and 53 patients who were treated with electrothermal bipolar vessel sealing (Caiman group: A). In group A, the Laparoscopic Caiman 5 (Aesculap AG, Tuttlingen, Germany) was the only instrument employed in the whole procedure. The study examined only three types of operation: right colectomy (RC), left colectomy (LC), and anterior resection (AR). Preoperative data were similar for RC, LC, and AR in both groups (A and B). The mean operative time was statistically shorter in the Caiman group than in the Historical group [104 vs 124min (p 0.004), 116 vs 140min (p 0.004), and 125 vs 151min (p 0.003) for RC, LC, and AR between group A and B, respectively]. Also intraoperative blood loss results significantly lower in the Caiman group than in the historical one [52ml vs 93 for RC (p 0.003); 65 vs 120ml for LC (p 0.001); 93 vs 145ml for AR (p 0.002) between group A and B, respectively]. No intraoperative complications were recorded in either group. The mean conversion rate was 4.4% (6 patients). There were no statistical differences in intensive care unit (ICU) stay, functional outcomes, mean hospital stay and overall morbidity rate between the two groups. There was no mortality in either group. The use of the Caiman EBVS instrument shows significant advantages with respect to a small number of intraoperative parameters. We can conclude that use of this radiofrequency device, in the laparoscopic approach, offers advantages in terms of lower intraoperative blood loss and shorter operative time in obese patients with colorectal cancer.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call