Abstract

There are several significant power quality and performance issues relating to energy efficient (EE) motors. This paper addresses some of these issues through detailed testing, analysis and comparison of standard (STD) and EE motors. The power quality issues addressed in this paper are over/under voltage and unbalanced supplies. The investigation was conducted on four (STD) and four EE motors, each group with ratings of 3kW, 7.5kW, 11kW and 15kW. It was found that the voltage unbalance results in a larger % current unbalance in EE motors. This is primarily due to the lower negative sequence impedance associated with EE motors. Experimental results verify the theoretical results. Furthermore, the experimental results show that the peak of the efficiency curves shift to lower loads during under-voltage conditions and towards higher loads during over-voltage.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.