Chemical sanitizers are routinely used during commercial flume washing of fresh-cut leafy greens to minimize cross-contamination from the water. This study assessed the efficacy of three chlorine treatments against Escherichia coli O157:H7 on iceberg lettuce, in wash water, and on surfaces of a pilot-scale processing line using flume water containing various organic loads. Iceberg lettuce (5.4 kg) was inoculated to contain 10(6) CFU/g of a 4-strain cocktail of nontoxigenic, green fluorescent protein-labeled, ampicillin-resistant E. coli O157:H7 and held for 24 h at 4°C before processing. Lettuce was shredded using a Urschel TransSlicer, step conveyed to a flume tank, washed for 90 s using water alone or one of three different sanitizing treatments (50 ppm of total chlorine either alone or acidified to pH 6.5 with citric acid or T-128) in water containing organic loads of 0, 2.5, 5, or 10% (wt/vol) blended iceberg lettuce, and then dried using a shaker table and centrifugal dryer. Next, three 5.4-kg batches of uninoculated iceberg lettuce were processed identically. Various product (25 g), water (50 ml), and equipment surface swab (100 cm(2)) samples were homogenized in neutralizing buffer, diluted appropriately, and plated on tryptic soy agar containing 0.6% (wt/vol) yeast extract and 100 ppm of ampicillin without prior 0.45- m m membrane filtration to quantify E. coli O157:H7. Organic load negatively impacted the efficacy of all three chlorine treatments (P < 0.05) at the end of processing, with typical E. coli O157:H7 reductions of >5 and 0.9 to 3.7 log CFU/ml for organic loads of 0 and 10%, respectively. Organic load rarely had a significant impact (P < 0.05) on the efficacy of chlorine, chlorine plus citric acid, or chlorine plus T-128 against E. coli O157:H7 on iceberg lettuce. Reduced sanitizer efficacy generally corresponded to changes in total solids, chemical oxygen demand, turbidity, and maximum filterable volume, indicating that these tests may be effective alternatives to the industry standard of oxygen/reduction potential.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.