Abstract
This paper is concerned with organic contamination from a partially fluorinated o-ring used in a furnace for a high-temperature process. The organic outgas was confirmed by Fourier transform infrared analysis of the furnace exhaust gas. Experiments from practical trench dynamic random access memory disclosed that outgassed organic contaminants from the nitride process would severely worsen the tunneling leakage current performance of the storage dielectric and lead to fatal yield loss even though the cell capacitance was almost uninfluenced. To eliminate this yield detractor requires several test runs prior to real production after installation of the partially fluorinated o-ring; otherwise, a fully fluorinated o-ring is needed. From a cost viewpoint, the latter is highly suggested.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.