Abstract

The energy requirements for an Electric Water Heater (EWH) accounts for 40% of a household’s total energy consumption and 7% of South Africa’s energy requirements. The flexibility of the device to store thermal energy for long periods highlights how the intensity of the grid demand can be alleviated by implementing demand-side management (DSM) strategies. In this paper, we evaluate energy savings that can be achieved by modelling the EWH as a variable number of multiple nodes and providing it with optimal control with perfect foreknowledge of the hot water usage profile. We simulated 77 household’s for all four seasons and determined that an average daily energy saving of 6.24% for temperature-matching and 16.3% for energy-matching can be achieved for a 20-node EWH. We also evaluated how increasing the number of nodes of the EWH when determining the optimal planning affects energy savings. It was concluded that using more than four nodes produced diminishing returns.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.