Abstract
Unlined iron pipe (UIP) is still widely in use in drinking water distribution systems (DWDS), discoloration easily happens after a long-time retention due to iron release, but the influence of initial chlorine on water quality under this condition is not clear. Here, we studied the water quality changes in UIP section reactors under different initial chlorine dosages. Results showed that chlorine could disappeared rapidly within 0.5 h in the UIP. The water with higher initial chlorine (5 mg/L) had higher turbidity in a short time (within 1.5 h), but for a longer retention time (2∼12 h), the highest turbidity was in the iron pipe without initial chlorine. Interestingly, a clear increase in adenosine triphosphate in the UIPs was observed with the increase of initial chlorine, which was in accordance with the results of heterotrophic plate count. Polysaccharide and protein increased with the increase of initial chlorine, which would benefit the formation of a protective layer to inhibit corrosion. This study reflects that during the overnight retention in UIP, raising chlorine would be effective to control discoloration, but chemical and microbiological risks may increase.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.