Abstract

PurposeThe aim of this study in a group of patients with primary aldosteronism was to evaluate the contribution of CB-CT (cone beam CT) to the overall success rate of adrenal vein sampling (AVS), and in particular to the selective cannulation of the right adrenal vein (RAV). MethodThis was a retrospective single-center study including 91 AVS procedures performed by our consultant radiologist between March 2011 and January 2017. Fifty cases were performed with CB-CT and 50 were performed without. Angiography with CB-CT was carried out after RAV cannulation to check the accurate catheter position. For each patient, we collected technical and biochemical success rates, as well as irradiation data. ResultsThe overall success rate of AVS with CB-CT was 80 %, vs. 44 % without (p = 0.00046), with right-sided selectivity of 88 % vs. 49 % (p < 0.0001). There was no significant increase in radiation exposure with CB-CT (p = 0.8206). Fluoroscopy time and quantity of iodine injected were significantly lower with CB-CT than without (p = 0.0039 and p < 0.0001). ConclusionCB-CT allows a better evaluation of the selectivity of right-sided adrenal catheterization and greatly increases the overall success rate of AVS.