Abstract
Experimental study of changing and blending combustion of Shenhua coal on boiler operation was carried out, while the furnace slagging during the experiment, the coal pulverizing system adjustment and the boiler operation oxygen control issues were analyzed. The results show that: the boiler can operate in safety blending Shenhua coal and Zhungeer coal with the ratio of 7:3 based on the strengthening laboratory analysis of coal as fired, the safety and economy of the boiler and coal pulverizing system can be ensured with the pulverized coal fineness R90 in 30%, and selecting the lower mill combinations and setting the coal pulverizer outlet temperature at 73°C, the reasonable exhaust gas oxygen content should be 4.0%, and the boiler thermal efficiency has an 1% increase compared with the condiation of burning inferior Shanxi bituminous coal, the nitrogen oxide emissions are significantly reduced.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.