Abstract
The influence of the building’s configuration on the air flow pattern and the amount of pollutant entering the buildings was investigated. Six common forms of low-rise buildings in Shiraz City were evaluated as investigated patterns. Each of these forms were placed in four rotation modes (24 case studies in total) in an urban regular pavilion-shaped context, placed in the vicinity of an urban highway (as a source of pollutant production) and were simulated using Computational Fluid Dynamics (CFD). In this research, air velocity and NO2 concentration were considered as the air quality parameters. Steady 3-dimensional flow was used to simulate these cases using the SST k-[Formula: see text] turbulence model, which was numerically solved based on the Reynolds-averaged Navier–Stokes (RANS) equations. The CFD software used in this research was validated in comparison with wind tunnel tests and acceptable results were found. The TOPSIS multi-criteria decision-making method was used to choose the best case based on increasing the air velocity and decreasing amount of pollutant inside the building. The results show that the best and worst building forms are related to the step-shaped and the L-shaped form, respectively. The results of this research provide design solutions for architects and urban designers to improve the ventilation quality of buildings.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.