The mechanical stability of Sn-Ag-Cu interconnects with low and high silver content against mechanical shock at room and elevated temperatures was investigated. With a heating element-embedded printed circuit board design, a test temperature from room temperature to 80°C was established. High impact shock tests were applied to isothermally pre-conditioned ball-grid array interconnects. Under cyclic shock testing, degradation and improved shock performances were identified associated with test temperature variation and non-solder mask defined and solder-mask defined pad design configuration differences. Different crack propagation paths were observed, induced by the effect of the elevated temperature test conditions and isothermal aging pre-conditions.