Abstract

Endoluminal repair of abdominal aortic aneurysms (AAA) is associated with decreased blood loss and transfusion requirements when compared to open AAA repair. We evaluated the use of an intraoperative autotransfusion system during endoluminal exclusion of AAAs. Fifty endoluminal AAA procedures selected at random were reviewed retrospectively. Patients were divided into 4 groups according to their estimated blood loss: Group I, 20 patients (0-500 cc); Group II, 18 patients (501-1,000 cc); Group III, 7 patients (1,001-1,500 cc); and Group IV, 5 patients (1,501-3,400 cc). The average blood loss was 327 cc for Group I, 728 cc for Group II, 1,217 for Group III, and 2,125, for Group IV. The overall blood loss was 834 cc, but 75 per cent was recovered. Hematuria was always present when greater than 1,000 cc of blood was retransfused, but renal function was not affected even with the concomitant administration of radiographic contrast. Only one patient required an autologous blood transfusion. The use of an autotransfusion device is safe, efficacious, and appears to further limit the need for homologous blood transfusion in patients undergoing endoluminal AAA repair.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.