Abstract

BackgroundImplementation of interventions to increase provider awareness of central venous catheters (CVC) and indwelling urinary catheters (IUC) and indications can impact device utilization rates. Device utilization rates (DUR) correlate with device-associated complications. We implemented a Daily Interdisciplinary Safety Huddle (DISH) involving all hospital units. Devices were reported and plans for removal reviewed. Barriers identified were addressed within 24 hours. The purpose of this study was to evaluate the impact of DISH on DUR and HAI at a 151-bed urban, community hospital.MethodsThis is a retrospective review of DUR for IUC, CVC and the relationship to HAI. DISH is a daily 15-minute meeting at 8am. Key participants include the chief nursing officer (CNO), infection control practitioner (ICP), and managers of all hospital units. CVC and IUC usage are reported by nurse managers. The ICP reviews indications, duration, and plans for device removal. When barriers for removal remain, such as provider preference, the CNO, Medical Director of Infection Control or Chief Quality Officer are involved. Data before and after implementation of DISH was compared. Paired T-test was used to assess for differences between DUR means of both groups.ResultsMean DUR for CVC was reduced from 0.2858 to 0.178 (device days/patient-days, P <0.001, CI 95%). For IUC, there was reduction from a mean of 0.586 to 0.176 (device days/patient-days, P <0.001, CI 95%). There was a significant reduction for IUC DUR in intensive care units (ICU) and non-ICU settings. The decrease in CVC DUR was significant in only the non-ICU setting.ConclusionHospital-wide reductions in DUR and HAI occurred after DISH. A 90% reduction in HAI occurred with estimated cost savings of $498,000. The impact of DISH was more profound in non-ICU settings, where devices may remain without indication or awareness. DISH may help mitigate this behavior. To our knowledge, a hospital-wide safety huddle with infection control components and its effect on DUR and HAIs has not been reported in the literature. DISH is a forum that promotes device removal, accountability and promotes a culture of safety.Figure 1.ICU IUC DURFigure 2.Non-ICU IUCFigure 3.ICU CVC DURTable 1.HAICAUTICLABSIBefore512After11Disclosures All authors: No reported disclosures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.