Abstract
This paper investigates the collapse characteristics of CF/Epoxy composite tubes subjected to axial loads as changing interlaminar number and outer ply orientation angle. The tubes are aften used for automobiles, aerospace vehicles, trains, ships, and elevators. We have performed static and dynamic impact collapse tests by a way of building impact test machine with vertical air-compression. It is fanad that CF/Epoxy tube of the 6 interlaminar number (C-type) with 90° outer orientation angle and trigger absorbed more energy than the other tubes (A, B and D types). Also collapse mode depended upon outer orientation angle of CF/Epoxy tubes and loading type as well ; typical collapse modes of CF/Epoxy tubes are wedged, splayed and fragmentcl.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.