Abstract
This paper makes simulation analysis on an electromagnetic valve product based on ANSYS software by changing the angle, position, length and permeability of electromagnet magnetic isolation ring, and get different electromagnetic force curves. According to electromagnetic force curves, it can verify the importance of magnetic isolation ring’s existence. Comparing simulation results curve with measured electromagnetic force curve, it can find that Attenuation trend of two curves are consistent, which can prove the reliability of simulation by ANSYS software. This study makes a series of electromagnetic force simulation by changing the angle, relative position, and length of magnetic isolation ring. The results show that the influence of relative position’s change to electromagnetic force is more obvious than other factors. The conclusion can be taken as reference by electromagnetic valve designers. Furthermore, there exists important application value in this series of electromagnetic valve optimal design process.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.