Abstract

Poor wind environment in residential areas leads to the accumulation of odor from domestic waste, affecting pedestrian health. A reasonable arrangement of waste collection points can reduce pedestrian exposure risks. This study aims to investigate the hydrogen sulfide (H2S) dispersion and residents’ exposure risk at the pedestrian level for five different locations of waste collection points in a residential building array. Simulation results are consistent with the benchmark wind tunnel experiment, validating that the used turbulence model and numerical methods show good agreement with the predictions of the aforementioned problem. Results indicate that the dimensionless concentration of H2S and personal intake fraction in a residential area are lower when the collection point is at the corner of the building array periphery. When the collection point is located in the middle of the periphery of the building array or between two adjacent buildings in the center of the array, the local dimensionless concentration of H2S is 50 at the pedestrian level, and the personal intake fraction is three orders of magnitude higher than that at the corner of the building array periphery. The findings provide a reference for the layout of waste collection points in high-density residential areas and reduction in outdoor exposure risk.