Abstract
Separate injections of Haemophilus influenzae type b capsular polysaccharide-tetanus conjugate (PRP-T) vaccine and diphtheria-tetanus-pertussis (DTP) reconstitution of freeze-dried PRP-T vaccine with liquid DTP vaccine have been shown to be safe and immunogenic in infants. The present study was conducted to test the safety and immunogenicity of the liquid combination vaccine administered to young infants in the dual-chamber syringe. The study was a monocenter, open clinical trial of 3 month-old infants receiving PRP-T and DTP vaccines in the dual-chamber syringe reconstituted prior to injection. Healthy infants were immunized according to a 3, 4 and 5 months-of-age schedule. The vaccine was administered in a dual-chamber syringe, ready to use with two chambers. The proximal chamber contained freeze-dried PRP-T and the distal chamber contained liquid combination-vaccine DTP. The freeze-dried PRP-T vaccine was reconstituted with the liquid DTP vaccine in the same unidose dual-chamber syringe (0.5 mL) and was injected intramuscularly into the deltoid region. Blood sampling was performed prior to vaccination at 3 months of age and after the third vaccination at 6 months. The primary end-point was the serological response to PRP-T vaccine as expressed by the percentage of infants with an antibody titer greater than or equal to 1 microgram/mL. The reactogenicity was expressed as the percentage of reported local and systemic reactions. A total of 108 infants were included in the study and received the dual-chamber syringe vaccine. After the third injection, all the infants had a PRP antibody titer greater than or equal to 0.15 microgram/mL and 94.4% of infants had a PRP antibody titer greater than or equal to 1 microgram/mL; the pertussis agglutinin titers were over the threshold 40 and 80 in all infants and 98.1% were over the threshold 320. After the third injection, all the infants had diphtheria antibody titers greater than 0.1 IU/mL and 83.3% had titers greater than 1 IU/mL; all the infants had tetanus antibody titers greater than 0.1 IU/mL and 97.2% had results over 1 IU/mL. Thirty-seven infants (34.6%) had local reactions and 64.5% had systemic reactions. The dual-chamber syringe may reduce the cost of vaccine delivery, as well as the workload, and increase the vaccine acceptability and coverage rate of vaccines.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.