Abstract

A higher rate of bioresorbable vascular scaffold (BVS) thrombosis has been observed after device implantation compared to implantation of permanent metallic stents in recently published studies. The mechanism of BVS thrombosis is currently under debate. To assess whether the immune-inflammatory response after BVS implantation is a potential trigger of BVS thrombosis. The PRAGUE-19 study was an academic study that enrolled consecutive patients with ST-segment elevation myocardial infarction (STEMI) with the intention to implant a BVS. A laboratory sub-study included 49 patients with an implanted BVS (of which 38 underwent the complete 2-year follow-up) and 52 patients having an implanted permanent metallic stent as the control group (of which 30 underwent the complete 2-year follow-up). Samples for inflammatory markers [high-sensitivity C-reactive protein (hs-CRP), interleukin-6 (IL-6) and tumor necrosis factor-alpha (TNF-α)] were taken before BVS or stent implantation, on days 1 and 2 after device implantation and at 1month and 2years for a clinical control. The primary combined clinical endpoint of the sub-study (death, reinfarction or target vessel revascularization) occurred in 4.08% of the BVS group and 7.69% of the control group (p = 0.442) during the 2-year follow-up period, with overall mortality of 2.04% in the BVS group and 1.92% in the control group (p = 0.966). Definite BVS thrombosis occurred in one patient in the subacute phase; there was no late or very late thrombosis. Two definite stent thromboses were observed in the control group: one inthe subacute phase and the other inthe late phase. Baseline inflammatory marker levels did not differ between the groups. Lower levels of IL-6 and hs-CRP were observed in the BVS group compared to the control group (12.02 ± 5.94 vs. 15.21 ± 5.33pg/ml; p < 0.01; 3952.9 ± 1704.75ng/ml vs. 4507.49 ± 1190.01ng/ml; p = 0.037, respectively) on days 1 and 2 (12.01 ± 6.31 vs. 13.85 ± 6.01pg/ml; p = 0.089; 4447.92 ± 1325.31ng/ml vs. 4637.03 ± 1290.99ng/ml; p = 0.255, respectively). No differences in IL-6 or hs-CRP were observed after 1month or 2years in the clinical control. Levels of TNF-α did not differ between the groups in the early period after BVS or metallic stent implantation, nor during follow-up. The immune-inflammatory response is lower during the early phase after BVS implantation compared to that after metallic stent implantation, but the responses did not differ in the long term.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call