Abstract
Whether to prophylactically irradiate the ipsilateral internal mammary chain (IMC) in post-mastectomy radiotherapy (PMRT) remains controversial because of equivocal clinical benefits against the added toxicities. Our previous study revealed that the cardiac dose was decreased during left-sided breast radiotherapy with abdominal deep inspiration breath-hold (aDIBH) as compared with free-breathing (FB) and thoracic deep inspiration breath-hold (tDIBH). Here we present the dosimetric advantage of aDIBH for patients undergoing PMRT with IMC coverage. We prospectively analyzed 19 patients with left-sided breast cancer who underwent PMRT. Patients underwent computed tomography (CT) simulation under both free-breathing (FB) and aDIBH. The heart, left anterior descending coronary artery (LAD), lungs, and the contralateral breast was defined as organs at risk (OARs). Three-dimensional conformal radiation therapy (3D-CRT), inverse planning intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT) were used to calculate the doses received by both the planning target volume (PTV) and OARs, which were compared using the Wilcoxon signed-rank test. Compared with FB, the Dmean of the heart and LAD were respectively reduced by 3.5 Gy (P<0.003) and 8.9 Gy (P<0.001) in 3D-CRT, 2.6 Gy (P<0.001), and 7.8 Gy (P=0.001) in IMRT, 1.5 Gy (P<0.001) and 4.5 Gy (P=0.001) in VMAT plans under aDIBH. Among all these plans, the Dmean of the heart was lowest in aDIBH IMRT and 1.3 Gy lower than in aDIBH VMAT (P=0.002). aDIBH IMRT also resulted in a significantly reduced dose to the ipsilateral lung than plans under FB (P<0.05). Dmean and V5 to the contralateral lung and breast were higher in VMAT plans (P<0.05). Using an immobilization-assisted aDIBH technique, radiation doses to the heart can be kept at reasonably low levels even if IMC is included in the clinical target volume (CTV). Among 3D-CRT, IMRT, and VMAT plans, IMRT plus aDIBH results in the best heart-sparing effect. We recommend that the aDIBH technique be routinely applied in suitable patients if the IMC is irradiated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.