Abstract

To compare different immobilization devices used for chest wall and nodal irradiation in breast cancer dosimetrically. All patients with left-sided breast cancer received chest wall and lymphatic irradiation. Treatment plans were created for radiotherapy in single arm (SA) lift board, double arm (DA) lift board, and wing board (WB) positions. Dose-volum e histograms (DVH) were used for evaluation based on planning target volume (PTV) coverage and organs at risk (OARs). One-way analysis of variance (ANOVA) test was performed to identify the dose-volume differences among different immobilization techniques. Clinically acceptable plans were generated with all immobilization boards. Significantly lower doses in the body except target volumes were found in the SA lift board group compared to other groups (P < 0.05). No relevant differences were observed among the plans according to the other dose parameters of target volumes and OARs. SA board is an immobilization device that can be used safely for three-dimensional conformal radiotherapy in young left-sided breast cancer with an unfavorable anatomy as it significantly reduces low-dose exposure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.