Abstract
The analysis of the signal transduction inhibitor imatinib in patient tumour tissue using LC and MS/MS is described. The anticancer agent is eluted over RP-C18 within 2 mm together with its internal standard STI571-d8. Calibration curves were prepared in red blood cells (RBC). For quantitative isolation of the RBC, measurement of sediment was applied. There were no indications of signal suppression by substances originating in the biological matrix. The limit of determination in tumour tissue was in the range of those recorded for RBC and plasma. The assay is selective and sensitive, with its robustness favouring the experimental application in clinical oncology and its routine use in animal experiments. The LOD was 4.5 ng per gram in tumour tissue.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.