Abstract

AbstractWe present the design and principle of operation of the imaging ion mass and velocity analyzer on the Enhanced Polar Outflow Probe (e‐POP), which measures low‐energy (1–90 eV/e) ion mass composition (1–40 AMU/e) and velocity distributions using a hemispherical electrostatic analyzer (HEA), a time‐of‐flight (TOF) gate, and a pair of toroidal electrostatic deflectors (TED). The HEA and TOF gate measure the energy‐per‐charge and azimuth of each detected ion and the ion transit time inside the analyzer, respectively, providing the 2‐D velocity distribution of each major ionospheric ion species and resolving the minor ion species under favorable conditions. The TED are in front of the TOF gate and optionally sample ions at different elevation angles up to ±60°, for measurement of 3‐D velocity distribution. We present examples of observation data to illustrate the measurement capability of the analyzer, and show the occurrence of enhanced densities of heavy “minor” O++, N+, and molecular ions and intermittent, high‐velocity (a few km/s) upward and downward flowing H+ ions in localized regions of the quiet time topside high‐latitude ionosphere.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.